MAN_Sanitary Revision_Body Temperature

Registration and control of the passenger's body temperature in the Check-in and / or boarding process.

The objective is to detect passengers who may have a fever and prevent dispersal and possible contagion COVID-19

Configuration


The mandatory use and control of temperature is configured from the JJCHK table. The available options are detailed below, please request the configuration from our helpdesk at host@kiusys.com or your account executive

The indicator can be found in section DEFAULT CHECK-IN INITIALIZATION within parameter [PBT]PASSENGER BODY TEMPERATURE

Options

Indicator

Description

Indicator

Description

NO

No mandatory use

CHK:YES-BRD:NO

Mandatory use at Check-in

CHK:NO-BRD:YES

Mandatory use at Boarding

CHK:YES-BRD:YES

Mandatory use at Check-in and Boarding

/ MAX. ALLOW: <valor>

Maximum temperature control to accept and / or board the passenger

Control Panel


The flights will be initialized according to the parameter configured in the airline's JJCHK table, the control will be seen under the TEMP: indicator followed by the parameter.

If the flight does not have mandatory control, the parameter will not be displayed in the display.

Users with keyword CHKLV1 or CHKLV2 could modify the control panel of a particular flight

Entry:

PC<flight>/<date><origin>,TEMP<parameter>

Parameter

Description

Parameter

Description

C

Control only at Check-in

B

Control only at Boarding

CB

Control at Check-in and Boarding

N

No mandatory use

Example:

PC4444/4SEPJFK,TEMPCB

PC4444/4SEPBOG,TEMPN

To check more details on

Accepting passangers with body temperature register


To accept a passenger indicating body temperature Duty 5 is required. The indicator is: ,PT<value> (passenger´s temperature).

  • The value may have up to 4 numeric characters including one decimal. Example: 35.6, 100.4

  • This indicator may be entered in field Other Elements of the graphic seat map.

  • If the indicator is mandatory and it is not detailed in the entry, the following error message will be displayed: INVALID - CHECK PASSENGER BODY TEMPERATURE

  • If the maximum value control is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one is entered: INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE

  • The accepting command accepts every option the PU command includes.

  • If connecting passengers are accepted, the temperature control will only apply to the first flight and not to the later ones, by definition the sanitary control corresponds to the airport where the passenger begins his itinerary.

Infant passengers are not considered in PT control, that means, they can be accepted with an adult who does have temperature control

Entry

PU<item number>,PT<value>

Example:

PU1,ST5A,PT23 CHECKIN->XX4444/28AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. NOKUUJ DD/DD PP 69720253 MDQ YY 5A 0/000
PU3,PT38 INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE PU3,PT37.7 CHECKIN->XX4444/29AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. UPHYVV PRUEBA TEST/QL PP 55015456 MDQ YY 9C 0/000
PU1 INVALID - CHECK PASSENGER BODY TEMPERATURE

To see more information on

Editing passengers with body temperature registration


Editing the value of a passenger on a flight with a body temperature indicator requires Duty 5, the indicator is: ,PT<value> (passenger´s temperature).

  • The new value entered replaces the previous one or adds it in case the passenger has been accepted without previous value.

  • You can remove the body temperature value only on those flights that do not require it as mandatory. The indicator is: ,PT0 or ,PTDEL

  • If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case an attempt is made to edit indicating a temperature higher than the allowed one: INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE

Entry:

PE<flight>/<date><rute>-<secuence number>,PT<value>

Example:

To read more information on Edición de Pasajeros Chequeados

Boarding passengers with body temperature registration


To board a passenger on a flight with a body temperature indicator Duty 5 is required, the indicator is: ,PT<value> (passenger´s temperature).

  • If the entry is mandatory and is not clarified in the boarding command, the value will display the following error message: INVALID - CHECK PASSENGER BODY TEMPERATURE

  • If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one, is entered: INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE

Entry

PB<secuence number>,PT<value>

Example:

To see more information of

History


All body temperature records remain in the flight history (PH command) with the indicated PT:<value>

Automatic or manual flight initialization also captures parameterized body temperature control with the indicator TEMP:<parameter>

Changes in temperature control in the Flight Control Panel are also reflected under the OPT indicator and the new value is recorded.

Filter / OPT can be applied in history to view all control changes in condensed form

To see more information of

Possible Errors


Error

Descripción

Error

Descripción

NEED DUTY

User does not have the required Duty

NEED KEYWORD

User does not have the required Keyword

INVALID - CHECK PASSENGER BODY TEMPERATURE

Checking passenger´s body temperature is mandatory

INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE

The value entered exceeds the maximun permitted