Registration and control of the passenger's body temperature in the Check-in and / or boarding process.

The objective is to detect passengers who may have a fever and prevent dispersal and possible contagion COVID-19

Configuration


The mandatory use and control of temperature is configured from the JJCHK table. The available options are detailed below, please request the configuration from our helpdesk at host@kiusys.com or your account executive

The indicator can be found in section DEFAULT CHECK-IN INITIALIZATION within parameter [PBT]PASSENGER BODY TEMPERATURE

Options

Indicator

Description

NO

No mandatory use

CHK:YES-BRD:NO

Mandatory use at Check-in

CHK:NO-BRD:YES

Mandatory use at Boarding

CHK:YES-BRD:YES

Mandatory use at Check-in and Boarding

/ MAX. ALLOW: <valor>

Maximum temperature control to accept and / or board the passenger

Control Panel


The flights will be initialized according to the parameter configured in the airline's JJCHK table, the control will be seen under the TEMP: indicator followed by the parameter.

If the flight does not have mandatory control, the parameter will not be displayed in the display.

  • TEMP:C Mandatory use only when accepting the passenger (comando PU)

  • TEMP:B Mandatory use only when boarding the passenger (comando PB)

  • TEMP:CB Mandatory use only when accepting and boarding the passenger (comando PU y PB)

Users with keyword CHKLV1 or CHKLV2 could modify the control panel of a particular flight

Entry:

PC<flight>/<date><origin>,TEMP<parameter>

Parameter

Description

C

Control only at Check-in

B

Control only at Boarding

CB

Control at Check-in and Boarding

N

No mandatory use

Example:

PC4444/4SEPJFK,TEMPCB

PC4444/4SEPBOG,TEMPN

To check more details on Panel de control

Accepting passangers with body temperature register


To accept a passenger indicating body temperature Duty 5 is required. The indicator is: ,PT<value> (passenger´s temperature).

  • The value may have up to 4 numeric characters including one decimal. Example: 35.6, 100.4

  • This indicator may be entered in field Other Elements of the graphic seat map.

  • If the indicator is mandatory and it is not detailed in the entry, the following error message will be displayed: INVALID - CHECK PASSENGER´S BODY TEMPERATURE

  • If the maximum value control is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one is entered: INVALID - PASSENGER´S BODY TEMPERATURE NOT ACCEPTED

  • The accepting command accepts every option the PU command includes.

  • If connecting passengers are accepted, the temperature control will only apply to the first flight and not to the later ones, by definition the sanitary control corresponds to the airport where the passenger begins his itinerary.

Infant passengers are not considered in PT control, that means, they can be accepted with an adult who does have temperature control

Entry

PU<item number>,PT<value>

Example:

PU1,ST5A,PT23
CHECKIN->XX4444/28AUG AEP
 ORD  CODE   NAME                      FOID            OFF CC PARTY NAT.  SEAT            H.BAG       BAG
 003. NOKUUJ DD/DD                     PP 69720253     MDQ YY             5A                            0/000
PU3,PT38
INVALIDO - TEMPERATURA CORPORAL DEL PASAJERO NO ES ACEPTABLE
PU3,PT37.7
CHECKIN->XX4444/29AUG AEP
 ORD  CODE   NAME                      FOID            OFF CC PARTY NAT.  SEAT            H.BAG       BAG
 003. UPHYVV PRUEBA TEST/QL            PP 55015456     MDQ YY             9C                            0/000
PU1
INVALIDO - CHEQUEAR TEMPERATURA CORPORAL DEL PASAJERO

To see more information on Aceptación de Pasajeros

Editing passengers with body temperature registration


Editing the value of a passenger on a flight with a body temperature indicator requires Duty 5, the indicator is: ,PT<value> (passenger´s temperature).

  • The new value entered replaces the previous one or adds it in case the passenger has been accepted without previous value.

  • You can remove the body temperature value only on those flights that do not require it as mandatory. The indicator is: ,PT0 or ,PTDEL

  • If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case an attempt is made to edit indicating a temperature higher than the allowed one: INVALID - PASSENGER´S BODY TEMPERATURE NOT ACCEPTED

Entry:

PE<flight>/<date><rute>-<secuence number>,PT<value>

Example:

PE4444/5JUNAEPMDQ-8,PT35
    CHECKIN-> XX4444/05JUN AEP

   ORD    CODE   NAME                        FOID              OFF  PARTY NAT.           SEAT  H.BAG   BAG
  #008.   LQLCEC ARIAS DE MONTILLA/MIRE      PP 78990925       MDQ                         5A         MDQ  1/010 (>XX005329) FF:1234567 WT:12 CT:A  

PE4444/5JUNAEPMDQ-8,PTDEL
    CHECKIN-> XX4444/05JUN AEP

   ORD    CODE   NAME                        FOID              OFF  PARTY NAT.           SEAT  H.BAG   BAG
  #008.   LQLCEC ARIAS DE MONTILLA/MIRE      PP 78990925       MDQ                         5A         MDQ  1/010 (>XX005329) FF:1234567 WT:12 CT:A
                 MBT:CIERR DOMES AEP-MDQ      

To read more information on Edición de Pasajeros Chequeados

Boarding passengers with body temperature registration


To board a passenger on a flight with a body temperature indicator Duty 5 is required, the indicator is: ,PT<value> (passenger´s temperature).

  • If the entry is mandatory and is not clarified in the boarding command, the value will display the following error message: INVALID - CHECK PASSENGER´S BODY TEMPERATURE

  • Si en el JJCHK esta configurado el control con valor máximo el agente de aeropuerto vera el siguiente error en caso que se ingrese una temperatura mayor a la permitida: INVALIDO - TEMPERATURA CORPORAL DEL PASAJERO NO ES ACEPTABLE

Sintaxis

PB<nro de secuencia>,PT<valor>

Ejemplo:

PB13,PT351
PAX BOARDED
PB14,PT39
INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE
PB14
INVALID - CHECK PASSENGER BODY TEMPERATURE

Ver mas información de Embarque de Pasajeros

Historial


Todos los registros de temperatura corporal quedan en el historial de vuelo (comando PH) con el indicaron PT:<valor>

PH4444/5JUNAEP
...
PU  #014 SANCHEZ/NOHEMI MARLENE MRS PP 60357953 CC:YY SEAT:SBY BAG:0/0 PT: 35.00 *BZ:   9990210022567C1
    MBT:CIERR DOMES 
    AEP-MDQAEPXX-GL 1826 5JUN20
...
PE  #008 PT: 38.00
AEPXX-GL 1855 5JUN20
...
PB  #013  PB13,PT35
AEPXX-GL 1831 5JUN20

La inicialización automática o manual del vuelo también captura el control parametrizado de temperatura corporal con el indicador TEMP:<parámetro>

PH4444/5JUNAEP
** HISTORY **
FLT: XX4444    BRD: AEP    FRI 05JUN20

CHK OPEN PCI4444 DEFAULT VALUES -> ETKT:Y , BRDP:Y , BAGT:Y , BOARDING: OPEN , NOOP:/AR1444, API:Y , NAT:Y , TEMP:CB
    AEPXX-GL 1442 5JUN20 

Los cambios del control de temperatura en el Panel de Control de vuelo también se reflejan bajo el indicador OPT y se registra el nuevo valor. Se puede aplicar el filtro /OPT en el historial para ver todos los cambios de control de forma condensada

PH4444/5JUNAEP/OPT
...
OPT SET TEMP:C
    AEPXX-GL 1455 5JUN20 
OPT SET  API:N
    AEPXX-GL 1456 5JUN20 
OPT SET TEMP:B
    AEPXX-GL 1457 5JUN20 
OPT SET TEMP:N
    AEPXX-GL 1457 5JUN20 
OPT SET TEMP:CB
    AEPXX-GL 1504 5JUN20 
...

Ver mas información de Historia del Vuelo

Posibles Errores


Error

Descripción

NEED DUTY

El usuario no tiene Duty para ejecutar la acción

NEED KEYWORD

El usuario no tiene keyword para ejecutar la acción

INVALIDO - CHEQUEAR TEMPERATURA CORPORAL DEL PASAJERO

El registro del valor de temperatura corporal es obligatorio

INVALIDO - TEMPERATURA CORPORAL DEL PASAJERO NO ES ACEPTABLE

El valor registrado super el máximo establecido.

  • No labels