Registration and control of the passenger's body temperature in the Check-in and / or boarding process.
The objective is to detect passengers who may have a fever and prevent dispersal and possible contagion COVID-19
Configuration
The mandatory use and control of temperature is configured from the JJCHK table. The available options are detailed below, please request the configuration from our helpdesk at host@kiusys.com or your account executive
The indicator can be found in section DEFAULT CHECK-IN INITIALIZATION
within parameter [PBT]PASSENGER BODY TEMPERATURE
Options
Indicator | Description |
---|---|
NO | No mandatory use |
CHK:YES-BRD:NO | Mandatory use at Check-in |
CHK:NO-BRD:YES | Mandatory use at Boarding |
CHK:YES-BRD:YES | Mandatory use at Check-in and Boarding |
/ MAX. ALLOW: <valor> | Maximum temperature control to accept and / or board the passenger |
Control Panel
The flights will be initialized according to the parameter configured in the airline's JJCHK table, the control will be seen under the TEMP: indicator followed by the parameter.
If the flight does not have mandatory control, the parameter will not be displayed in the display.
TEMP:C
Mandatory use only when accepting the passenger (comando PU)TEMP:B
Mandatory use only when boarding the passenger (comando PB)TEMP:CB
Mandatory use only when accepting and boarding the passenger (comando PU y PB)
Users with keyword CHKLV1 or CHKLV2 could modify the control panel of a particular flight
Entry:
PC<flight>/<date><origin>,TEMP<parameter>
Parameter | Description |
---|---|
C | Control only at Check-in |
B | Control only at Boarding |
CB | Control at Check-in and Boarding |
N | No mandatory use |
Example:
PC4444/4SEPJFK,TEMPCB
PC4444/4SEPBOG,TEMPN
To check more details on Panel de control
Accepting passangers with body temperature register
To accept a passenger indicating body temperature Duty 5 is required. The indicator is: ,PT<value>
(passenger´s temperature).
The value may have up to 4 numeric characters including one decimal. Example: 35.6, 100.4
This indicator may be entered in field Other Elements of the graphic seat map.
If the indicator is mandatory and it is not detailed in the entry, the following error message will be displayed:
INVALID - CHECK PASSENGER´S BODY TEMPERATURE
If the maximum value control is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one is entered:
INVALID - PASSENGER´S BODY TEMPERATURE NOT ACCEPTED
The accepting command accepts every option the PU command includes.
If connecting passengers are accepted, the temperature control will only apply to the first flight and not to the later ones, by definition the sanitary control corresponds to the airport where the passenger begins his itinerary.
Infant passengers are not considered in PT control, that means, they can be accepted with an adult who does have temperature control
Entry
PU<item number>,PT<value>
Example:
PU1,ST5A,PT23 CHECKIN->XX4444/28AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. NOKUUJ DD/DD PP 69720253 MDQ YY 5A 0/000
PU3,PT38 INVALIDO - TEMPERATURA CORPORAL DEL PASAJERO NO ES ACEPTABLE PU3,PT37.7 CHECKIN->XX4444/29AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. UPHYVV PRUEBA TEST/QL PP 55015456 MDQ YY 9C 0/000
PU1 INVALIDO - CHEQUEAR TEMPERATURA CORPORAL DEL PASAJERO
To see more information on Aceptación de Pasajeros
Editing passengers with body temperature registration
Editing the value of a passenger on a flight with a body temperature indicator requires Duty 5, the indicator is: ,PT<value>
(passenger´s temperature).
The new value entered replaces the previous one or adds it in case the passenger has been accepted without previous value.
You can remove the body temperature value only on those flights that do not require it as mandatory. The indicator is:
,PT0
or,PTDEL
If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case an attempt is made to edit indicating a temperature higher than the allowed one:
INVALID - PASSENGER´S BODY TEMPERATURE NOT ACCEPTED
Entry:
PE<flight>/<date><rute>-<secuence number>,PT<value>
Example:
PE4444/5JUNAEPMDQ-8,PT35 CHECKIN-> XX4444/05JUN AEP ORD CODE NAME FOID OFF PARTY NAT. SEAT H.BAG BAG #008. LQLCEC ARIAS DE MONTILLA/MIRE PP 78990925 MDQ 5A MDQ 1/010 (>XX005329) FF:1234567 WT:12 CT:A PE4444/5JUNAEPMDQ-8,PTDEL CHECKIN-> XX4444/05JUN AEP ORD CODE NAME FOID OFF PARTY NAT. SEAT H.BAG BAG #008. LQLCEC ARIAS DE MONTILLA/MIRE PP 78990925 MDQ 5A MDQ 1/010 (>XX005329) FF:1234567 WT:12 CT:A MBT:CIERR DOMES AEP-MDQ
To read more information on Edición de Pasajeros Chequeados
Boarding passengers with body temperature registration
To board a passenger on a flight with a body temperature indicator Duty 5 is required, the indicator is: ,PT<value>
(passenger´s temperature).
If the entry is mandatory and is not clarified in the boarding command, the value will display the following error message:
INVALID - CHECK PASSENGER´S BODY TEMPERATURE
Si en el JJCHK esta configurado el control con valor máximo el agente de aeropuerto vera el siguiente error en caso que se ingrese una temperatura mayor a la permitida:
INVALIDO - TEMPERATURA CORPORAL DEL PASAJERO NO ES ACEPTABLE
Sintaxis
PB<nro de secuencia>,PT<valor>
Ejemplo:
PB13,PT351 PAX BOARDED
PB14,PT39 INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE
PB14 INVALID - CHECK PASSENGER BODY TEMPERATURE
Ver mas información de Embarque de Pasajeros
Historial
Todos los registros de temperatura corporal quedan en el historial de vuelo (comando PH) con el indicaron PT:<valor>
PH4444/5JUNAEP ... PU #014 SANCHEZ/NOHEMI MARLENE MRS PP 60357953 CC:YY SEAT:SBY BAG:0/0 PT: 35.00 *BZ: 9990210022567C1 MBT:CIERR DOMES AEP-MDQAEPXX-GL 1826 5JUN20 ... PE #008 PT: 38.00 AEPXX-GL 1855 5JUN20 ... PB #013 PB13,PT35 AEPXX-GL 1831 5JUN20
La inicialización automática o manual del vuelo también captura el control parametrizado de temperatura corporal con el indicador TEMP:<parámetro>
PH4444/5JUNAEP ** HISTORY ** FLT: XX4444 BRD: AEP FRI 05JUN20 CHK OPEN PCI4444 DEFAULT VALUES -> ETKT:Y , BRDP:Y , BAGT:Y , BOARDING: OPEN , NOOP:/AR1444, API:Y , NAT:Y , TEMP:CB AEPXX-GL 1442 5JUN20
Los cambios del control de temperatura en el Panel de Control de vuelo también se reflejan bajo el indicador OPT y se registra el nuevo valor. Se puede aplicar el filtro /OPT en el historial para ver todos los cambios de control de forma condensada
PH4444/5JUNAEP/OPT ... OPT SET TEMP:C AEPXX-GL 1455 5JUN20 OPT SET API:N AEPXX-GL 1456 5JUN20 OPT SET TEMP:B AEPXX-GL 1457 5JUN20 OPT SET TEMP:N AEPXX-GL 1457 5JUN20 OPT SET TEMP:CB AEPXX-GL 1504 5JUN20 ...
Ver mas información de Historia del Vuelo
Posibles Errores
Error | Descripción |
---|---|
| El usuario no tiene Duty para ejecutar la acción |
| El usuario no tiene keyword para ejecutar la acción |
| El registro del valor de temperatura corporal es obligatorio |
| El valor registrado super el máximo establecido. |