The indicator can be found in section DEFAULT CHECK-IN INITIALIZATION
within parameter [PBT]PASSENGER BODY TEMPERATURE
Options
Indicator | Description |
---|---|
NO | No mandatory use |
CHK:YES-BRD:NO | Mandatory use at Check-in |
CHK:NO-BRD:YES | Mandatory use at Boarding |
CHK:YES-BRD:YES | Mandatory use at Check-in and Boarding |
/ MAX. ALLOW: <valor> | Maximum temperature control to accept and / or board the passenger |
Control Panel
...
The flights will be initialized according to the parameter configured in the airline's JJCHK table, the control will be seen under the TEMP: indicator followed by the parameter.
...
TEMP:C
Mandatory use only when accepting the passenger (comando PUhttps://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#Accepting-passengers-without-a-seat-or-bags )TEMP:B
Mandatory use only when boarding the passenger (comando PBhttps://kiu.atlassian.net/wiki/spaces/KOD/pages/4146090/MAN+Boarding )TEMP:CB
Mandatory use only when accepting and boarding the passenger (comando PU y PBhttps://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#Accepting-passengers-without-a-seat-or-bags and https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146090/MAN+Boarding )
Users with keyword CHKLV1 or CHKLV2 could modify the control panel of a particular flight
...
PC<flight>/<date><origin>,TEMP<parameter>
Parameter | Description |
---|---|
C | Control only at Check-in |
B | Control only at Boarding |
CB | Control at Check-in and Boarding |
N | No mandatory use |
Example:
PC4444/4SEPJFK,TEMPCB
PC4444/4SEPBOG,TEMPN
To check more details on Panel de control https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146039/MAN+Control+Panel
Accepting passangers with body temperature register
...
The value may have up to 4 numeric characters including one decimal. Example: 35.6, 100.4
This indicator may be entered in field Other Elements of the graphic seat map.
If the indicator is mandatory and it is not detailed in the entry, the following error message will be displayed:
INVALID - CHECK PASSENGER´S PASSENGER BODY TEMPERATURE
If the maximum value control is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one is entered:
INVALID - PASSENGER´S PASSENGER BODY TEMPERATURE NOT ACCEPTEDACCEPTABLE
The accepting command accepts every option the PU command includes.
If connecting passengers are accepted, the temperature control will only apply to the first flight and not to the later ones, by definition the sanitary control corresponds to the airport where the passenger begins his itinerary.
...
Code Block |
---|
PU1,ST5A,PT23 CHECKIN->XX4444/28AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. NOKUUJ DD/DD PP 69720253 MDQ YY 5A 0/000 |
Code Block |
---|
PU3,PT38 INVALIDOINVALID - TEMPERATURAPASSENGER CORPORALBODY DELTEMPERATURE PASAJERONOT NOACCEPTABLE ES ACEPTABLE PU3,PT37.7 CHECKIN->XX4444/29AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. UPHYVV PRUEBA TEST/QL PP 55015456 MDQ YY 9C 0/000 |
Code Block |
---|
PU1 INVALIDOINVALID - CHEQUEARCHECK TEMPERATURAPASSENGER CORPORALBODY DEL PASAJEROTEMPERATURE |
To see more information on Aceptación de Pasajeros https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#Accepting-passengers-without-a-seat-or-bags
Editing passengers with body temperature registration
...
The new value entered replaces the previous one or adds it in case the passenger has been accepted without previous value.
You can remove the body temperature value only on those flights that do not require it as mandatory. The indicator is:
,PT0
or,PTDEL
If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case an attempt is made to edit indicating a temperature higher than the allowed one:
INVALID - PASSENGER´S PASSENGER BODY TEMPERATURE NOT ACCEPTEDACCEPTABLE
Entry:
PE<flight>/<date><rute>-<secuence number>,PT<value>
...
If the entry is mandatory and is not clarified in the boarding command, the value will display the following error message:
INVALID - CHECK PASSENGER´S PASSENGER BODY TEMPERATURE
Si en el JJCHK esta configurado el control con valor máximo el agente de aeropuerto vera el siguiente error en caso que se ingrese una temperatura mayor a la permitida:
INVALIDO - TEMPERATURA CORPORAL DEL PASAJERO NO ES ACEPTABLE
Sintaxis
PB<nro de secuencia>,PT<valor>
...
If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one, is entered:
INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE
Entry
PB<secuence number>,PT<value>
Example:
Code Block |
---|
PB13,PT351 PAX BOARDED |
...
Code Block |
---|
PB14 INVALID - CHECK PASSENGER BODY TEMPERATURE |
Ver mas información de Embarque de Pasajeros
Historial
Todos los registros de temperatura corporal quedan en el historial de vuelo (comando PH) con el indicaron PT:<valor>
To see more information of https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#Editing-details-for-passengers-already-accepted
History
...
All body temperature records remain in the flight history (PH command) with the indicated PT:<value>
Code Block |
---|
PH4444/5JUNAEP ... PU #014 SANCHEZ/NOHEMI MARLENE MRS PP 60357953 CC:YY SEAT:SBY BAG:0/0 PT: 35.00 *BZ: 9990210022567C1 MBT:CIERR DOMES AEP-MDQAEPXX-GL 1826 5JUN20 ... PE #008 PT: 38.00 AEPXX-GL 1855 5JUN20 ... PB #013 PB13,PT35 AEPXX-GL 1831 5JUN20 |
La inicialización automática o manual del vuelo también captura el control parametrizado de temperatura corporal con el indicador TEMP:<parámetro>
Automatic or manual flight initialization also captures parameterized body temperature control with the indicator TEMP:<parameter>
Code Block |
---|
PH4444/5JUNAEP ** HISTORY ** FLT: XX4444 BRD: AEP FRI 05JUN20 CHK OPEN PCI4444 DEFAULT VALUES -> ETKT:Y , BRDP:Y , BAGT:Y , BOARDING: OPEN , NOOP:/AR1444, API:Y , NAT:Y , TEMP:CB AEPXX-GL 1442 5JUN20 |
Los cambios del control de temperatura en el Panel de Control de vuelo también se reflejan bajo el indicador OPT y se registra el nuevo valor. Se puede aplicar el filtro /OPT en el historial para ver todos los cambios de control de forma condensadaChanges in temperature control in the Flight Control Panel are also reflected under the OPT indicator and the new value is recorded.
Filter / OPT can be applied in history to view all control changes in condensed form
Code Block |
---|
PH4444/5JUNAEP/OPT ... OPT SET TEMP:C AEPXX-GL 1455 5JUN20 OPT SET API:N AEPXX-GL 1456 5JUN20 OPT SET TEMP:B AEPXX-GL 1457 5JUN20 OPT SET TEMP:N AEPXX-GL 1457 5JUN20 OPT SET TEMP:CB AEPXX-GL 1504 5JUN20 ... |
Ver mas información de Historia del Vuelo
...
To see more information of https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#History
Possible Errors
...
Error | Descripción |
---|---|
|
User does not have the required Duty |
|
El usuario no tiene keyword para ejecutar la acción
INVALIDO - CHEQUEAR TEMPERATURA CORPORAL DEL PASAJERO
El registro del valor de temperatura corporal es obligatorio
INVALIDO - TEMPERATURA CORPORAL DEL PASAJERO NO ES ACEPTABLE
User does not have the required Keyword | |
| Checking passenger´s body temperature is mandatory |
| The value entered exceeds the maximun permitted |