Registration and control of the passenger's body temperature in the Check-in and / or boarding process.
The objective is to detect passengers who may have a fever and prevent dispersal and possible contagion COVID-19
Configuration
The mandatory use and control of temperature is configured from the JJCHK table. The available options are detailed below, please request the configuration from our helpdesk at host@kiusys.com or your account executive
The indicator can be found in section DEFAULT CHECK-IN INITIALIZATION
within parameter [PBT]PASSENGER BODY TEMPERATURE
Options
Indicator | Description |
---|---|
NO | No mandatory use |
CHK:YES-BRD:NO | Mandatory use at Check-in |
CHK:NO-BRD:YES | Mandatory use at Boarding |
CHK:YES-BRD:YES | Mandatory use at Check-in and Boarding |
/ MAX. ALLOW: <valor> | Maximum temperature control to accept and / or board the passenger |
Control Panel
The flights will be initialized according to the parameter configured in the airline's JJCHK table, the control will be seen under the TEMP: indicator followed by the parameter.
If the flight does not have mandatory control, the parameter will not be displayed in the display.
TEMP:C
Mandatory use only when accepting the passenger (https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#Accepting-passengers-without-a-seat-or-bags )TEMP:B
Mandatory use only when boarding the passenger (https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146090/MAN+Boarding )TEMP:CB
Mandatory use only when accepting and boarding the passenger (https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#Accepting-passengers-without-a-seat-or-bags and https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146090/MAN+Boarding )
Users with keyword CHKLV1 or CHKLV2 could modify the control panel of a particular flight
Entry:
PC<flight>/<date><origin>,TEMP<parameter>
Parameter | Description |
---|---|
C | Control only at Check-in |
B | Control only at Boarding |
CB | Control at Check-in and Boarding |
N | No mandatory use |
Example:
PC4444/4SEPJFK,TEMPCB
PC4444/4SEPBOG,TEMPN
To check more details on https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146039/MAN+Control+Panel
Accepting passangers with body temperature register
To accept a passenger indicating body temperature Duty 5 is required. The indicator is: ,PT<value>
(passenger´s temperature).
The value may have up to 4 numeric characters including one decimal. Example: 35.6, 100.4
This indicator may be entered in field Other Elements of the graphic seat map.
If the indicator is mandatory and it is not detailed in the entry, the following error message will be displayed:
INVALID - CHECK PASSENGER BODY TEMPERATURE
If the maximum value control is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one is entered:
INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE
The accepting command accepts every option the PU command includes.
If connecting passengers are accepted, the temperature control will only apply to the first flight and not to the later ones, by definition the sanitary control corresponds to the airport where the passenger begins his itinerary.
Infant passengers are not considered in PT control, that means, they can be accepted with an adult who does have temperature control
Entry
PU<item number>,PT<value>
Example:
PU1,ST5A,PT23 CHECKIN->XX4444/28AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. NOKUUJ DD/DD PP 69720253 MDQ YY 5A 0/000
PU3,PT38 INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE PU3,PT37.7 CHECKIN->XX4444/29AUG AEP ORD CODE NAME FOID OFF CC PARTY NAT. SEAT H.BAG BAG 003. UPHYVV PRUEBA TEST/QL PP 55015456 MDQ YY 9C 0/000
PU1 INVALID - CHECK PASSENGER BODY TEMPERATURE
To see more information on https://kiu.atlassian.net/wiki/spaces/KOD/pages/4146086/MAN+Passenger+Acceptance#Accepting-passengers-without-a-seat-or-bags
Editing passengers with body temperature registration
Editing the value of a passenger on a flight with a body temperature indicator requires Duty 5, the indicator is: ,PT<value>
(passenger´s temperature).
The new value entered replaces the previous one or adds it in case the passenger has been accepted without previous value.
You can remove the body temperature value only on those flights that do not require it as mandatory. The indicator is:
,PT0
or,PTDEL
If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case an attempt is made to edit indicating a temperature higher than the allowed one:
INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE
Entry:
PE<flight>/<date><rute>-<secuence number>,PT<value>
Example:
PE4444/5JUNAEPMDQ-8,PT35 CHECKIN-> XX4444/05JUN AEP ORD CODE NAME FOID OFF PARTY NAT. SEAT H.BAG BAG #008. LQLCEC ARIAS DE MONTILLA/MIRE PP 78990925 MDQ 5A MDQ 1/010 (>XX005329) FF:1234567 WT:12 CT:A PE4444/5JUNAEPMDQ-8,PTDEL CHECKIN-> XX4444/05JUN AEP ORD CODE NAME FOID OFF PARTY NAT. SEAT H.BAG BAG #008. LQLCEC ARIAS DE MONTILLA/MIRE PP 78990925 MDQ 5A MDQ 1/010 (>XX005329) FF:1234567 WT:12 CT:A MBT:CIERR DOMES AEP-MDQ
To read more information on Edición de Pasajeros Chequeados
Boarding passengers with body temperature registration
To board a passenger on a flight with a body temperature indicator Duty 5 is required, the indicator is: ,PT<value>
(passenger´s temperature).
If the entry is mandatory and is not clarified in the boarding command, the value will display the following error message:
INVALID - CHECK PASSENGER BODY TEMPERATURE
If the control with maximum value is configured in the JJCHK, the airport agent will see the following error in case a higher temperature than the allowed one, is entered:
INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE
Entry
PB<secuence number>,PT<value>
Example:
PB13,PT351 PAX BOARDED
PB14,PT39 INVALID - PASSENGER BODY TEMPERATURE NOT ACCEPTABLE
PB14 INVALID - CHECK PASSENGER BODY TEMPERATURE
To see more information of Embarque de Pasajeros
History
All body temperature records remain in the flight history (PH command) with the indicated PT:<value>
PH4444/5JUNAEP ... PU #014 SANCHEZ/NOHEMI MARLENE MRS PP 60357953 CC:YY SEAT:SBY BAG:0/0 PT: 35.00 *BZ: 9990210022567C1 MBT:CIERR DOMES AEP-MDQAEPXX-GL 1826 5JUN20 ... PE #008 PT: 38.00 AEPXX-GL 1855 5JUN20 ... PB #013 PB13,PT35 AEPXX-GL 1831 5JUN20
Automatic or manual flight initialization also captures parameterized body temperature control with the indicator TEMP:<parameter>
PH4444/5JUNAEP ** HISTORY ** FLT: XX4444 BRD: AEP FRI 05JUN20 CHK OPEN PCI4444 DEFAULT VALUES -> ETKT:Y , BRDP:Y , BAGT:Y , BOARDING: OPEN , NOOP:/AR1444, API:Y , NAT:Y , TEMP:CB AEPXX-GL 1442 5JUN20
Changes in temperature control in the Flight Control Panel are also reflected under the OPT indicator and the new value is recorded.
Filter / OPT can be applied in history to view all control changes in condensed form
PH4444/5JUNAEP/OPT ... OPT SET TEMP:C AEPXX-GL 1455 5JUN20 OPT SET API:N AEPXX-GL 1456 5JUN20 OPT SET TEMP:B AEPXX-GL 1457 5JUN20 OPT SET TEMP:N AEPXX-GL 1457 5JUN20 OPT SET TEMP:CB AEPXX-GL 1504 5JUN20 ...
To see more information of Historia del Vuelo
Posible Errors
Error | Descripción |
---|---|
| User does not have the required Duty |
| User does not have the required Keyword |
| Checking passenger´s body temperature is mandatory |
| The value entered exceeds the maximun permitted |